OEM Factory for Trace Oxygen Analyser - Nernst N6000 oxygen analyzer – Litong

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

That has a sound business enterprise credit rating, exceptional after-sales provider and modern producing facilities, we now have earned an superb standing amongst our buyers across the world for Flue Gas Analysis, Maintenance Free Zirconia Probe, Nitrox Oxygen Analyzer, We've been willing to provide you with the lowest selling price during the market place, greatest high quality and quite nice sales service.Welcome to do bussines with us,let's be double win.
OEM Factory for Trace Oxygen Analyser - Nernst N6000 oxygen analyzer – Litong Detail:

Application range

The Nernst N6000 oxygen analyzer is widely used in the detection of oxygen content in the combustion process of electric power, metallurgy, steel, chemical industry, ceramics, incineration, etc.It can also directly monitor the oxygen content in the flue gas of boilers, kilns, sintering furnaces, heating furnaces, pit annealing furnaces, etc. during or after combustion.During the measurement, the temperature in the furnace and the flue can be from normal temperature to 900°C high temperature.The oxygen analyzer provides real-time oxygen content O2% (percentage) parameters and oxygen potential millivolt values in the furnace or flue.

In the high dust and high corrosive gas environment,the N6000 oxygen analyzer can be set to periodically purge the zirconia probe, which greatly increases the life of the in-line zirconia probe and reduces the cost of use.

Technical characteristics

 Input function: One oxygen analyzer can be connected to a oxygen probe to display the measured oxygen content in real time.

• Multi-channel output control: the analyzer has one 4-20mA current output.

 Measurement range: The oxygen measurement range is 10-38 to 100% oxygen.

• Alarm setting: The analyzer has 1 general alarm output and 3 programmable alarm outputs.

 Automatic calibration: The analyzer has an automatic calibration function, and the user can customize the calibration time and number of calibrations according to their needs.

• Automatic dust cleaning: The analyzer has the function of automatically cleaning the probe. The user can clean the probe regularly according to the needs, eliminating the need for manual on-site dust cleaning. 

• Intelligent system: The analyzer can complete the functions of various settings according to the predetermined settings.

• Display output function: The analyzer can display the date, current oxygen content, probe temperature, current oxygen millivolt value and 14 first-level status displays and 11 second-level status displays.

 Safety function: When the furnace is out of use, the user can control to turn off the heater of the probe to ensure safety during use.

 Installation is simple and easy: the installation of the analyzer is very simple and there is a special cable to connect with the zirconia probe. The N6000 oxygen analyzer can also be integrated with the automatic purging system in an integrated protective box, which is very convenient for installation and operation.

Specifications

Inputs

One zirconia oxygen probes or sensors

Outputs

Linear 4~20mA DC

Display mode

128×64 dot liquid crystal display

Probe heating method

PID control

Dust cleaning and standard gas calibration

The analyzer has an automatic calibration function and an automatic dust cleaning function.It can also automatically control the solenoid valve switch.

ary Parameter Display

AlarmsParameter Display

High and low oxygen alarms can be set arbitrarily.

AccuracyP

± 1% of the actual oxygen reading with a repeatability of 0.5%.

Reaction rateP

Indirect heating measurement is about 3 seconds

Direct heating in 30 seconds

Core detection reaction speed: 0.0001s

Range of Local Indication

9.985E-1~5.952E-38

-33.4mV~1800.0mV(720°C)

Reference gas

There is a miniature brushless motor vibration pump in the analyzer for reference gas.

Power Ruireqements

85VAC to 264VAC 3A

Operating Temperature

Operating Temperature -25°C to 55°C

Relative Humidity 5% to 95% (non-condensing)

Degree of Protection

IP67

Dimensions and Weight

230mm W x 220mm H x 95mm D   3kg


Product detail pictures:

OEM Factory for Trace Oxygen Analyser - Nernst N6000 oxygen analyzer  – Litong detail pictures


Related Product Guide:

We not only will try our greatest to offer you excellent services to just about every client, but also are ready to receive any suggestion offered by our buyers for OEM Factory for Trace Oxygen Analyser - Nernst N6000 oxygen analyzer – Litong, The product will supply to all over the world, such as: Johor, Casablanca, Rotterdam, We always stick to the tenet of "sincerity, high quality, high efficiency, innovation". With years of efforts, we have established friendly and stable business relationships with worldwide customers. We welcome any of your inquiries and concerns for our products, and we are sure that we will offer just what you want, as we always believe that your satisfaction is our success.
  • This is a very professional and honest Chinese supplier, from now on we fell in love with the Chinese manufacturing.
    5 Stars By Samantha from Ecuador - 2017.06.25 12:48
    This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Mamie from Bangalore - 2018.07.26 16:51

    Related Products