With advanced technologies and facilities, strict high quality regulate, reasonable price tag, excellent support and close co-operation with shoppers, we have been devoted to furnishing the best benefit for our buyers for Steam Oven Water Vapor Analyzer, Hmw Water Vapour Probe, O2 Analysis, Welcome worldwide customers to contact us for business and long-term cooperation. We will be your reliable partner and supplier.
High Quality Acid Dew Point Analyzer - Nernst N2038 high temperature dew point analyzer – Litong Detail:

Application range

The Nernst N2038 high temperature dew point analyzer is used for continuous online measurement of the dew point or micro-oxygen content in the high-temperature annealing furnace with full hydrogen or nitrogen-hydrogen mixed gas as the protective atmosphere.

Application characteristics

The Nernst 2038 high temperature dew point analyzer or high temperature micro oxygen analyzer is used to monitor the dew point value or micro oxygen in the furnace when the cold-rolled steel sheet is annealed in the annealing furnace. In order to avoid various problems caused by the oxidation reaction of the steel surface with oxygen during high temperature annealing.

It is well known that there are oxygen and water vapor in the annealing furnace. When the oxygen content is higher than 10-22% in a high temperature environment or when the water vapor decomposes into oxygen and hydrogen at a high temperature, the oxygen in the atmosphere will oxidize with the steel plate.

When the oxygen in the furnace is less than 10-15%, it is difficult to directly measure the oxygen content with the usual oxygen measurement method.

Because the oxygen in the furnace and the hydrogen in the protective atmosphere will react to produce water at high temperatures. Extract the gas in the furnace, measure the dew point value with a dew point meter, and then use the dew point value to convert it to the oxygen content in the furnace.Since it has not been possible to solve the problem of directly measuring micro-oxygen in a high-temperature furnace in the past, the method of measuring the dew point value in the furnace is used instead of measuring the micro-oxygen in the furnace, and the dew point value is used instead of the oxygen value.

The Nernst series of probes and analyzers can directly measure the micro-oxygen value in the protective atmosphere in the furnace with an accuracy of up to 10-30%, and users can convert it to the corresponding dew point value according to their needs.

This reliable, high-precision direct oxygen measurement method can replace the traditional method of measuring the dew point value in the protective atmosphere in the furnace with a dew point meter.

However, users who are accustomed to using the dew point method can still use the method they are familiar with to determine the micro-oxygen content in the furnace atmosphere through the dew point value.

Technical characteristics

 Two probes measurement: One dew point analyzer with two probes can save installation costs and improve reliability.

Multi-channel output control: The analyzer has two 4-20mA current output and computer communication interface RS232 or network communication interface RS485

 Measurement range: The oxygen measurement range is 10-30 to 100% oxygen,

-60°C~+40°C dew point value

Alarm setting: The analyzer has 1 general alarm output and 3 programmable alarm outputs.

 Automatic calibration: The analyzer will automatically monitor various functional systems and automatically calibrate to ensure the accuracy of the analyzer during measurement.

• Intelligent system: The analyzer can complete the functions of various settings according to the predetermined settings.

• Display output function: The analyzer has a strong function of displaying various parameters and a strong output and control function of various parameters.

 Safety function: When the furnace is out of use, the user can control to turn off the heater of the probe to ensure safety during use.

 Installation is simple and easy: the installation of the analyzer is very simple and there is a special cable to connect with the zirconia probe.

Specifications

Inputs

• One or two zirconia oxygen probes or sensors

• Three way K-type or R-type thermocouple

• Remote alarm input

• Remote pressure cleaning input

• Safety control input

Outputs

• Two linear 4~20mA (milliampere) or DC voltage DC output

• Maximum load 1000R (ohm)

• One way general alarm output

• Two controllable calibration gas

• One way dust-cleaning gas output

Main Parameter Display

• Oxygen content: from 10-30 to 100%

• Dew point value: from – 60°C to + 40°C

Secondary Parameter Display

Any or all of the following can be selected for display on the lower line:

• Probe #1 dew point value

• Probe #2 dew point value

• Average dew point of probe #1 and probe #2

• Year, month, day and minute display

• Run time display

• Maintenance time display

• Oxygen content of probe #1

• Oxygen content of probe #2

• Average oxygen content of probe #1 and probe #2

• Probe #1 signal voltage value

• Probe #2 signal voltage value

• Probe #1 temperature value

• Probe #2 temperature value

• Auxiliary input temperature value

• Probe #1 impedance value

• Probe #2 impedance value

• Ambient temperature value

• Ambient humidity valuecondary Parameter Displayy Parameter Display

AccuracyP

± 1% of the actual oxygen reading with a repeatability of 0.5%.

Serial/Network Interface

RS232

RS485 MODBUSTM

Reference gas

Reference gas adopts micro-motor vibration pump

Power Ruireqements

85VAC to 240VAC 3A

Operating Temperature

Operating Temperature -25°C to 55°C

Relative Humidity 5% to 95% (non-condensing)

Degree of Protection

IP65

IP54 with internal reference air pump

Dimensions and Weight

280mm W x 180mm H x 95mm D 3.5kg


Product detail pictures:

High Quality Acid Dew Point Analyzer - Nernst N2038 high temperature dew point analyzer – Litong detail pictures


Related Product Guide:

Our pursuit and enterprise goal is to "Always satisfy our customer requirements". We keep on to establish and style and design outstanding top quality goods for both our outdated and new prospects and realize a win-win prospect for our clientele likewise as us for High Quality Acid Dew Point Analyzer - Nernst N2038 high temperature dew point analyzer – Litong, The product will supply to all over the world, such as: Greek, Luxembourg, Eindhoven, We supply skilled service, prompt reply, timely delivery, excellent quality and best price to our customers. Satisfaction and good credit to every customer is our priority. We focus on every detail of order processing for customers till they have received safe and sound items with good logistics service and economical cost. Depending on this, our products and solutions are sold very well in the countries in Africa, the Mid-East and Southeast Asia. Adhering to the business philosophy of ??customer first, forge ahead', we sincerely welcome clients from at home and abroad to cooperate with us.
  • The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
    5 Stars By Rebecca from Berlin - 2017.04.28 15:45
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Delia Pesina from Armenia - 2018.12.11 11:26

    Related Products