New Product Release | Nernst NP35A Portable Acid Dew Point Analyzer is Now on the Market:
Precise Monitoring+Convenient Operation, Building a Strong Anti Corrosion Line for Industrial Equipment
In production scenarios such as industrial boilers, power plants, and metallurgical kilns, precise monitoring of flue gas acid dew point is a key link in preventing equipment low-temperature corrosion and ensuring stable system operation. Traditional acid dew point monitoring equipment generally suffers from pain points such as complex installation, easy drift in accuracy, and inconvenient on-site operation, which brings many difficulties to enterprise operation and maintenance.
Now, a new portable acid dew point analyzer integrating high-precision measurement, intelligent operation, and portable design has been officially launched. With multiple core technological breakthroughs, it provides efficient and reliable solutions for acid dew point monitoring in industrial sites.
Starting from the actual needs of industrial users, the Nernst NP35A portable acid dew point analyzer has achieved comprehensive upgrades in functional design:
1. Exclusive probe configuration, suitable for on-site monitoring needs. The instrument is equipped with a dedicated acid dew point probe input function. One analyzer can directly connect to one dedicated probe without the need for additional transfer equipment, simplifying the on-site connection process while ensuring signal transmission stability and accurately capturing flue gas acid dew point data.
2. Multi channel data output, compatible with industrial system integration, equipped with two 4-20mA standard current outputs, and supporting RS232 computer communication interface or RS485 network communication interface. It can seamlessly connect with industrial equipment such as DCS control system and data acquisition terminal, realize real-time transmission, remote monitoring and centralized management of acid dew point data, and meet the digital operation and maintenance needs of different enterprises.
3. High precision measurement performance ensures accurate and reliable data measurement range covering 0~200 ° C TD, with a measurement accuracy of up to ± 0.5% and a repeatability accuracy of ± 0.2%, far exceeding traditional monitoring equipment. Whether in high-temperature flue gas environments or dew point fluctuations under complex working conditions, stable and accurate measurement data can be provided, providing scientific basis for equipment corrosion prevention decisions.
4. Multi level alarm function, preventing equipment corrosion risks. Built in 1 universal alarm output and 3 programmable alarm outputs. Users can freely set the acid dew point alarm parameters according to the equipment safety threshold. When the monitoring data exceeds the safe range, the instrument automatically triggers an alarm and promptly reminds the operation and maintenance personnel to take protective measures to avoid corrosion and damage to pipelines, heat exchangers, and other equipment caused by low acid dew points.
5. Intelligent automatic calibration reduces manual maintenance costs. Equipped with an intelligent self check and automatic calibration system, it can monitor the operation status of various functional modules of the instrument in real time and automatically complete parameter calibration without frequent manual debugging, effectively reducing maintenance workload and ensuring long-term stable operation of the instrument.
6. Human computer interaction design simplifies the on-site operation process and is equipped with an intelligent human-machine dialogue system. Operators can complete various tasks such as parameter settings, data queries, and functional debugging through a convenient interface. Even non professionals can quickly get started and improve on-site monitoring efficiency.
7. Safety protection design extends the service life of equipment. For industrial site equipment shutdown maintenance scenarios, an independent control function for sensor heaters has been designed. When the furnace is no longer in use, users can manually turn off the sensor heater to avoid empty burning and loss of the heater, significantly extending the service life of the sensor and reducing equipment maintenance costs.
8. Portable without installation, adaptable to multiple scenarios and flexible monitoring. Breaking through the limitations of traditional fixed monitoring equipment, it adopts a portable design and does not require complex installation processes. On site, only dedicated cables are needed to connect probes and analyzers to quickly carry out acid dew point monitoring work. Especially suitable for multi-point inspection, temporary working condition monitoring, equipment troubleshooting and other scenarios, greatly enhancing the flexibility of monitoring work.
In on-site testing at a thermal power plant, the portable acid dew point analyzer successfully solved the pain points of traditional equipment installation complexity, data drift, and high maintenance costs with accurate measurement data, convenient operation procedures, and stable operating performance. By monitoring the acid dew point of the tail flue gas of the boiler in real-time, the operation and maintenance team adjusted the exhaust temperature in a timely manner, effectively avoiding low-temperature corrosion problems, reducing equipment operation and maintenance costs by 15%, and improving equipment operation stability by 20%.
The launch of the Nernst NP35A portable acid dew point analyzer provides a more efficient, economical, and reliable option for acid dew point monitoring in the industrial field. In the future, we will continue to focus on the actual needs of industrial users, constantly iterate and upgrade product technology, and safeguard the safe and efficient operation of industrial production!
Post time: Jan-12-2026